Detection method:
Online oil in water sensor, Commonly used oil-in-water detection methods are suspension method (D/λ<=1), infrared spectrophotometry (not suitable for low range), and ultraviolet spectrophotometry (not suitable for high range).
Features of Online oil-in-water sensor:
Using the principle of fluorescence. Compared with several commonly used methods, the fluorescence method is more efficient, faster, and can be monitored online in real time.
Technical parameter:
Product | Oil in water sensor/Self-cleaning oil in water sensor |
Model | DS530 |
Principle | Ultraviolet fluorescence method |
Measuring Range | 0-200ppm (Small range oil in water sensor 0-5ppm can be customized) |
Precision | 3% |
Resolution | 0.1ppm or 0.1ppb |
The detection limit | According to the actual oil sample |
Linearity | R2>0.999 |
Protection level | Ip68 |
Sensor interface | Support RS-485, MODBUS protocol |
Assembly | Input type |
Power information | DC 6-12V, current <50mA (when not cleaned) |
Size | Φ45*175.8 mm |
Probe cable length | 5 meters (default), can be customized |
Housing material | 316L (customizable titanium alloy) |
Self-cleaning Brush | No/Have |
Optical window | optical fiber |
Advantage:
The oil in water sensor has better repeatability and stability. The use of self-cleaning brushes can eliminate air bubbles, reduce the influence of pollution on the measurement, make the maintenance cycle longer, and maintain excellent stability for long-term online use. It can play an early warning role in oil pollution in water.
Installation Case:
It is suitable for water quality monitoring scenarios such as oil quality monitoring, industrial circulating water, condensate water, wastewater treatment, and surface water stations.