T311A series economical temperature contro

Heating-cooling dual PID control Timed insulation control function Extended self-tuning function, optional 50% or 90% tuning algorithm Alarm indication function, optional lower display window display Reinforced insulation design, power circuit, housing and other anti-electric shock protection in accordance with IEC61010-1 standardHeating-cooling dual PID control Timed insulation control function Extended self-tuning function, optional 50% or 90% tuning algorithm Alarm indication function, optional lower display window display Reinforced insulation design, power circuit, housing and other anti-electric shock protection in accordance with IEC61010-1 standard

āļˆāļģāļ™āļ§āļ™
āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āļŠāļīāļ™āļ„āđ‰āļē

Electrical Parameter Table

Sampling speed2 times/second
Relay capacityAC 250V/3A rated load lifespan greater than 100,000 cycles
Power supplyAC/DC 100-240V (85-265V), DC 24V
Total power consumption< 6VA
Solid-state relay outputDC 24V pulse level, with load <30mA
Insulation resistanceInput, output, and power supply to casing >20MÎĐ
Electrostatic dischargeIEC/EN61000-4-2 Contact Âą4KV/Air Âą8KV performance criteria B
Pulse group immunityIEC/EN61000-4-4 Âą2KV performance criteria B
Surge immunityIEC/EN61000-4-5 Âą2KV performance criteria B
Voltage dip and short interruption immunityIEC/EN61000-4-29 0% - 70% performance criteria B
Isolation withstand voltageSignal input and output and power supply AC3000V 1min, AC500V between low voltage circuits below 60V, 1min
Power outage data protection10 years, rewrite cycles 1 million times

 

Non-Electrical Parameter Table

Panel protection levelIP65 (IEC60529)
Safety standardsIEC61010-1 overvoltage category II, pollution degree 2, level II (reinforced insulation)
Casing materialCasing and panel base frame PC/ABS (flammability UL94V-0)Casing and panel base frame PC/ABS (flammability UL94V-0)
Surface materialPC
Total weightAbout 400g
Storage environmentStorage environmentStorage environment-10~60, no condensation
Surrounding environmental conditionsIndoor use, temperature: 0~50 no condensation, humidity:<85%RH, altitude less than 2000m

 

Measurement Signal Parameter

ModelInput Type SymbolResolutionAccuracyInput Impedance/AuxiliaryCurrent
T311A-
_-T_ _
K1-50 ï―ž 12001°C0.5%F.SÂą3digits>500KÎĐ
K2-50.0 ï―ž 999.90.2°C0.5%F.SÂą1°C>500kÎĐ
J10 ï―ž 12001°C0.5%F.SÂą3digits>500KÎĐ
J20.0 ï―ž 999.90.2°C0.5%F.SÂą1°C>500KÎĐ
E10 ï―ž 8501°C0.5%F.SÂą3digits>500KÎĐ
E20.0 ï―ž 850.00.3°C0.5%F.SÂą1>500KÎĐ
T150 ï―ž 4001°C0.8%F.SÂą3>500KÎĐ
T2-50.0 ï―ž 400.00.4°C0.8%F.SÂą3>500KÎĐ
B250 ï―ž 18001°C1%F.SÂą21%F.SÂą2>500KÎĐ
R-10 ï―ž 17001°C1%F.SÂą2>500KÎĐ
S-10 ï―ž 16001°C1%F.SÂą2>500KÎĐ
N1-50 ï―ž 12001°C0.8%F.SÂą1>500KÎĐ
N2-50.0 ï―ž 999.90.2°C0.8%F.SÂą1>500KÎĐ
T311A-
_-P_ _
PT100-1-200.0 ï―ž 600.00.2°C0.5%F.SÂą0.30.2mA
PT100-2-200 ï―ž 6001°C0.5%F.SÂą3digits0.2mA
JPT100-1-200.0 ï―ž 500.00.2°C0.5%F.SÂą0.30.2mA
JPT100-2-200 ï―ž 5001°C0.5%F.SÂą3digits0.2mA
CU50-1-50.0 ï―ž 150.00.2°C0.5%F.SÂą30.2mA
CU50-2-50 ï―ž 1501°C0.5%F.SÂą30.2mA
CU100-1-50.0 ï―ž 150.00.2°C0.5%F.SÂą10.2mA
CU100-2-50 ï―ž 1501°C0.5%F.SÂą3digits0.2mA

*Note: Please specify signal input requirements when placing an order.



āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ™āļĩāđ‰āļĄāļĩāļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āļ„āļļāļāļāļĩāđ‰ āđ€āļžāļ·āđˆāļ­āđ€āļžāļīāđˆāļĄāļ›āļĢāļ°āļŠāļīāļ—āļ˜āļīāļ āļēāļžāđāļĨāļ°āļ›āļĢāļ°āļŠāļšāļāļēāļĢāļ“āđŒāļ—āļĩāđˆāļ”āļĩāđƒāļ™āļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ‚āļ­āļ‡āļ—āđˆāļēāļ™ āļ—āđˆāļēāļ™āļŠāļēāļĄāļēāļĢāļ–āļ­āđˆāļēāļ™āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āđ€āļžāļīāđˆāļĄāđ€āļ•āļīāļĄāđ„āļ”āđ‰āļ—āļĩāđˆ āļ™āđ‚āļĒāļšāļēāļĒāļ„āļ§āļēāļĄāđ€āļ›āđ‡āļ™āļŠāđˆāļ§āļ™āļ•āļąāļ§ āđāļĨāļ° āļ™āđ‚āļĒāļšāļēāļĒāļ„āļļāļāļāļĩāđ‰