H8100 Multifunction Data Digital Display Instrument


รายละเอียดสินค้า
ดาวน์โหลด

HOLYKELL's "paperless" data logger is developed based on RJ45, printer or USB interface. It can not only provide on-site measurement data, but also recall historical data. Support standard voltage, current, resistance temperature measurement or millivolt signal output.

Application :

  • Use with pressure, level and flow meter

  • High-precision measurement

  • Diesel generators

  • Refinery

Advantages

01 "Paperless" design, environmentally friendly and supports multiple signal output.
02 RS232/485, RJ45, printer or USB interface are optional.
03 Display data in real time and recall historical data.
04 One of the most professional manufacturers of digital display instruments in China.

Technical Data

Measurement input 

 

 Input signal

Current: 0~20mA,0~10mA, 4~20mA, 0~10mA evolution, 4~20mA evolution
Voltage: 0~5V,1~5V,0~10V, ±5V, 0~5V evolution, 1~5V evolution, 0~20 mV, 0~100mV, ±20mV, ±100mV
Resistance thermometer connector: Pt100, Cu50, Cu53, BA1, BA2
Linear resistance: 0~400Ω
Thermoelectric couple: B, S, K, E, T, J, R, N, F2, Wre3-25 and Wre5-26
Output 

 

 

 

Output signal

Analog output: 4~20mA (load resistance380Ω) ,0~20mA (load resistance380Ω) ,0~10mA (load resistance750Ω) 1~5V (load resistance 250KΩ) ,0~5V (load resistance 250KΩ) and 0~10V (load resistance 500KΩ)
Alarm output: Normally-open output of relay, contact capacity 1A/250VAC (Resistive load)
Feed output: DC24V±1,load current250mA
Communication output: RS485/RS232 communication interface,baud rate1200~57600bps(settable) The standards are listed as follows: MODBUS RTU communication protocol,maximum RS-485 communication distance: 1km; maximum RS-232 communication distance: 15m; Ethernet communication interface,communication speed10M,(merely applicable to Local Area Network)
Composite parameters 
Measurement accuracy0.2%FS±1d
Sampling period1second
Setting modeLight-touch key setting; password locking of parameter setting value; permanent saving of setting value outage
Display mode7-inch 800*480 dot matrix widescreen, TFT high-brightness color graphic LCD, LED backlight, clear display and wide visual angle.
The screen brightness is adjustable. The display contents consist of Chinese characters, figures, process curves and bar graphics. By pressing the key on the panel, you can complete page turning, historical data search and modification of curve time scale, etc.
Data backupSupport USB and SD card for data backup and transfer, maximum capacity: 8GB, support FAT and FAT32 formats.
Storage capacityInternal Flash storage capacity: 64M Byte
Time interval of recordingTime interval for selection: 1, 2, 4, 6, 15, 30, 60, 120, 240(Unit: second)
Time duration of storage (Continuous record without power failure)4days(1-second time interval)5625 days(240-second time interval)
Formula:
(Note: Calculation of channel number: The program will divide the channel into five classes of 6, 16, 32 and 64. When the channel falls within the range of two classes, the bigger one should be taken. If, for instance, the channel number is 12, the number of 16 should be taken as the channel number.)


เว็บไซต์นี้มีการใช้งานคุกกี้ เพื่อเพิ่มประสิทธิภาพและประสบการณ์ที่ดีในการใช้งานเว็บไซต์ของท่าน ท่านสามารถอ่านรายละเอียดเพิ่มเติมได้ที่ นโยบายความเป็นส่วนตัว และ นโยบายคุกกี้
เปรียบเทียบสินค้า
0/4
ลบทั้งหมด
เปรียบเทียบ
Powered By MakeWebEasy Logo MakeWebEasy