KD600E series inverter is designed motor type according to the carrying characteristics of elevator. It adopts high performance vector control technology, can control both asynchronous motor and synchronous motor. For asynchronous motor open-loop vector control, it combined with innovative sensor start/stop compensation technology without weighting to ensure the comfort when elevator start/stop without weighting device.
AC Drive Model | Adapter motor (KW) | Rated input Current (A) | Rated output Current (A) | Installation size (mm) | Dimension (mm) | Aperture | |||
A | B | H | W | D | d | ||||
Input voltage: single-phase 220V Range: -15%~+20% | |||||||||
KD600E-2S-0.4G | 0.4 | 5.4 | 2.3 | 76 | 156 | 165 | 86 | 140 | 5 |
KD600E-2S-0.7G | 0.75 | 8.2 | 4.0 | ||||||
KD600E-2S-1.5G | 1.5 | 14.0 | 7.0 | ||||||
Input voltage: three-phase 380V Range: -15%~+20% | |||||||||
KD600E-4T-0.7G/1.5P | 0.7 | 3.4 | 2.1 | 76 | 156 | 165 | 86 | 140 | 5 |
KD600E-4T-1.5G/2.2P | 1.5 | 5.0 | 3.8 | ||||||
KD600E-4T-2.2G/4.0P | 2.2 | 5.8 | 5.1 | ||||||
KD600E-4T-4.0G/5.5P | 4.0 | 10.5 | 9.0 | 98 | 182 | 192 | 110 | 165 | 5 |
KD600E-4T-5.5G/7.5P | 5.5 | 14.6 | 13.0 | ||||||
KD600E-4T-7.5G/9.0P | 7.5 | 20.5 | 17.0 | 111 | 223 | 234 | 123 | 176 | 6 |
KD600E-4T-9.0G/11P | 9.0 | 22.0 | 20.0 | ||||||
KD600E-4T-11G/15P | 11 | 26.0 | 25.0 | 147 | 264 | 275 | 160 | 186 | 6 |
KD600E-4T-15G/18.5P | 15 | 35.0 | 32.0 | ||||||
KD600E-4T-18.5G/22P | 18.5 | 38.5 | 37.0 | 174 | 319 | 330 | 189 | 186 | 6 |
KD600E-4T-22G/30P | 22 | 46.5 | 45.0 | ||||||
KD600E-4T-30G/37P | 30 | 62 | 60 | 200 | 410 | 425 | 255 | 206 | 7 |
KD600E-4T-37G/45P | 37 | 76 | 75 | ||||||
KD600E-4T-45G/55P | 45 | 92 | 91 | 245 | 518 | 534 | 310 | 258 | 10 |
KD600E-4T-55G/75P | 55 | 113 | 110 | ||||||
KD600E-4T-75G/90P | 75 | 157 | 152 | 290 | 544 | 560 | 350 | 268 | 10 |
KD600E-4T-90G/110P | 90 | 180 | 176 | ||||||
KD600E-4T-110G/132P | 110 | 214 | 210 | 320 | 678 | 695 | 410 | 295 | 10 |
KD600E-4T-132G/160P | 132 | 256 | 253 | ||||||
KD600E-4T-160G/185P | 160 | 307 | 304 | 380 | 1025 | 1050 | 480 | 330 | 10 |
KD600E-4T-185G/200P | 185 | 345 | 340 | ||||||
KD600E-4T-200G/220P | 200 | 385 | 380 | ||||||
KD600E-4T-220G/250P | 220 | 430 | 426 | 500 | 1170 | 1200 | 590 | 365 | 14 |
KD600E-4T-250G/280P | 250 | 468 | 465 | ||||||
KD600E-4T-280G/315P | 280 | 525 | 520 | ||||||
KD600E-4T-315G/350P | 315 | 590 | 585 | 500 | 1255 | 1290 | 700 | 400 | 16 |
KD600E-4T-350G/400P | 350 | 665 | 650 | ||||||
KD600E-4T-400G/450P | 400 | 785 | 725 | ||||||
KD600E-4T-450G/500P | 450 | 883 | 820 | / | / | 1800 | 1000 | 500 | / |
KD600E-4T-500G/550P | 500 | 920 | 900 | ||||||
KD600E-4T-550G/630P | 550 | 1020 | 1000 | ||||||
KD600E-4T-630G/710P | 630 | 1120 | 1100 | ||||||
KD600E-4T-710G/800P | 710 | 1315 | 1250 | / | / | 2200 | 1200 | 600 | / |
KD600E-4T-800G/900P | 800 | 1525 | 1450 |
Specifications Table
Input & Output | |
---|---|
Input voltage | 1AC 220~240V(± 15%) 3AC 220~240V(± 15%) 3AC 380~460V(± 15%) |
Input frequency | 50Hz/60Hz ±5% |
Output voltage | 0~input voltage, deviation <±3% |
Output frequency | 0~600Hz |
Control Characteristics | |
---|---|
Control mode | V/f control Sensor-less vector control Torque control |
Speed accuracy | ±0.5% (V/f) ±0.2% (SVC) |
Speed fluctuation | ±0.3% (SVC) |
torque response | < 10ms (SVC) |
Starting torque | 0.5Hz: 150% (V/f) 0.25Hz: 180% (SVC) |
Overload capability | 150% Rated current -60s 180% Rated current -10s 200% Rated current -1s |
Simple PLC Multi-step speed | 16 speed External digital signal control Internal clock |
PID function | Standard build-in |
Communication | Modbus |
Featured Functions and Environment Limitation Table
Featured functions | |
---|---|
Featured functions | Input &Output delay Flexible parameters display AVR (Automatic Voltage Regulation) Timing control, fixed length control, etc. Simple PLC, 16-steps speed control Torque control build-in S curve acceleration/deceleration Multi-functional programmable keypad V/f separated control |
Environment Limitation | |
---|---|
Installation location | Without direct sunlight,free from dust,corrosive gases, oil mist, flammable gases, water vapor, water drop and salt,etc. |
Altitude | 0~2000m Derated 1% for every 1000m when the altitude is above 1000meters |
Ambient temperature | -10°C~50°C (Output derated while the temperature is higher than 40°C) |
Storage temperature | -20°C~+70°C |
Relative Humidity | 5-95% no condensation |
Expansion Cards and Accessories Table
Name | Model | Function |
---|---|---|
I/O expansion card 1 | KD600-IO1 | 5 digital inputs, one relay output, one analog AO2 output, one digital Y2 output, and one temperature detection (PT100/PT1000/PTC/KTY). |
I/O expansion card 2 | KD600-IO2 | Two digital inputs, one relay output, one analog AO2 output, and one LCD expansion network port RJ45 socket. |
RS-485 communication card | KD600-ISO485 | One isolated MoDBus communication adapter card |
CAN communication expansion card | KD600-CAN | CANOPEN communication adapter card |
ProFinet communication card | KD600-PN | ProFinet communication card |
Profbus-DP communication card | KD600-DP | Profbus-DP communication card |
Ethercat communication card | KD600-Ethercat | Ethercat communication card |
Open collector ABZ encoder | KD600-PG1 | Open collector PG card (PG card 1 can only be applied to asynchronous machines, compatible with complementary output, the encoder card output DC power supply can be selected +12V or +5V (jumper selection)) |
Differential input ABZ encoder card | KD600-PG3 | ABZ differential signal input PG card |
Resolver Interface Card | KD600-PG6 | Applicable to resolver, DB9 interface, optional matching shielded encoder cable. |
LCD screen | KD600-LCD | The LCD screen needs to be used with a IO2 expansion card. |
Analog Speed Given
KD600E supports two kinds of speed given: Analog speed given and multi-stage speed given; Life controller sends out speed command curve, inverter get speed given command through the analog signal.
Multi-stage speed given
Elevator controller provide speed command, after receving the command, inverter will automatically calculate S curve acceleration and deceleration speed.
Built-in Emergency leveling mode
In the using of elevator, if the power is cut suddenly, passengers may be kept in the cage. KD600E series interters can support emergency UPS power running, Both the main circult of KD600E and the working are powered by 220V UPS.