Precession vortex flow meter adopts micro-processing technology, which has the advantages of strong function, wide flow range, simple operation and maintenance, and convenient installation and use.
Application :
Advantages
01 No mechanical moving parts, corrosion resistance, stability and reliability, long life, long-term operation without special maintenance.
02 Mechatronics is realized, and the daily measurement process does not need to be manned.
03 The flow measurement range is wide (qmax/qmin=15-20), and it can work effectively in the small flow area that the orifice plate and vortex flowmeter cannot reach.
04 The instrument manager does not need professional training, and the measurement parameters such as flow, pressure and temperature can be directly read from the meter, and no conversion is required.
Technical Data
DN (mm) | Type | Flow range(m3/ h) | Working Pressure(MPa) | Accuracy | Repeatability |
15 | 1.0-10 | 1.6 2.5 4.0 6.3 10 16 | 1.0 1.5 | Less than 1/3 of the absolute value of the basic error limit | |
20 | 1.5-15 | ||||
25 | 3.0-30 | ||||
32 | 6.0~60 | ||||
40 | 7.0~70 | ||||
50 | A | 12~150 | |||
B | 2.5~75 | ||||
80 | A | 40~400 | |||
B | 10~200 | ||||
100 | A | 80~900 | |||
B | 30~600 | ||||
150 | A | 150~1500 | |||
B | 40~900 | ||||
200 | 240~3600 | 1.6;2.5;4.0 |